The posttrialsignal attribute specifies that after running a trial, Inquisit should wait for a signal from an external device before moving on to the next trial.
Applies to
<trial> <likert> <openended> <namingtrial>
Syntax
/ posttrialsignal = (modality, signal)Parameters
| modality | One of the following values:
|
||||||||||
| signal | An integer representing the numeric signal to wait for. If the modality is keyboard, this is the scancode of the key. |
Remarks
This is useful for requiring a second confirmation response from subjects before proceding to the next trial, or for synchronizing Inquisit with an external device such as an EEG.
Examples
The following trial waits for a signal value of 8 on the COM1 port before advancing to the next trial:
<trial mytrial>
/ stimulusframes = [1=sometext]
/ validresponse = (57)
/ posttrialsignal = (com1, 8)
</trial>